DEHNcombo
Result: 4/4 Products
Product 900070 was added to Notepad.
Product 900070 was added to the cart.
SPD according to EN 61643-31 / IEC 61643-31 | type 1 + type 2 / class I + class II |
Max. PV voltage [DC+ -> DC-] (UCPV ) | ≤ 1200 V |
Max. PV voltage [DC+/DC- -> PE] (UCPV ) | ≤ 1200 V |
Short-circuit current rating (ISCPV ) | 10 kA |
Nominal discharge current (8/20 µs) (In ) | 20 kA |
Max. discharge current (8/20 µs) (Imax ) | 40 kA |
Total discharge current (8/20 µs) [DC+/DC- -> PE] (Itotal ) | 40 kA |
Total discharge current (10/350 µs) [DC+/DC- -> PE] (Itotal ) | 12.5 kA |
Lightning impulse current (10/350 µs) [DC+ -> PE/DC- -> PE] (Iimp ) | 6.25 kA |
Voltage protection level [(DC+/DC-) -> PE] (UP ) | < 3.8 kV |
Voltage protection level [DC+ -> DC-] (UP ) | < 3.8 kV |
Response time (tA ) | ≤ 25 ns |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
For mounting on | 35 mm DIN rails acc. to EN 60715 |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 20 |
Dimensions | 4 module(s), DIN 43880 |
Approvals | KEMA, UL |
Extended technical data: | --------------------------------- |
– Use in DC battery storage systems up to ISCCR | ≤ 100 kA (t ≤ 5.83 ms) |
– Backup fuse for DC battery storage systems up to ISCCR | Bussman HLS 2000Vdc / 200 A 2+/A173 DST aR, manufacturer's Part. No.: 170M2040 |
– Backup fuse for DC battery storage systems up to ISCCR | Mersen Protistor D122SD20C200QF 200A 2000V DC aR |
Product 900071 was added to Notepad.
Product 900071 was added to the cart.
SPD according to EN 61643-31 / IEC 61643-31 | type 1 + type 2 / class I + class II |
Max. PV voltage [DC+ -> DC-] (UCPV ) | ≤ 1500 V |
Max. PV voltage [DC+/DC- -> PE] (UCPV ) | ≤ 1500 V |
Short-circuit current rating (ISCPV ) | 10 kA |
Nominal discharge current (8/20 µs) (In ) | 20 kA |
Max. discharge current (8/20 µs) (Imax ) | 40 kA |
Total discharge current (8/20 µs) [DC+/DC- -> PE] (Itotal ) | 40 kA |
Total discharge current (10/350 µs) [DC+/DC- -> PE] (Itotal ) | 12.5 kA |
Lightning impulse current (10/350 µs) [DC+ -> PE/DC- -> PE] (Iimp ) | 6.25 kA |
Voltage protection level [(DC+/DC-) -> PE] (UP ) | < 4.5 kV |
Voltage protection level [DC+ -> DC-] (UP ) | < 4.5 kV |
Response time (tA ) | ≤ 25 ns |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
For mounting on | 35 mm DIN rails acc. to EN 60715 |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 20 |
Dimensions | 4 module(s), DIN 43880 |
Approvals | KEMA, UL |
Extended technical data: | --------------------------------- |
– Use in DC battery storage systems up to ISCCR | ≤ 100 kA (t ≤ 5.83 ms) |
– Backup fuse for DC battery storage systems up to ISCCR | Bussman HLS 2000Vdc / 200 A 2+/A173 DST aR, manufacturer's Part. No.: 170M2040 |
– Backup fuse for DC battery storage systems up to ISCCR | Mersen Protistor D122SD20C200QF 200A 2000V DC aR |
Product 900075 was added to Notepad.
Product 900075 was added to the cart.
SPD according to EN 61643-31 / IEC 61643-31 | type 1 + type 2 / class I + class II |
Max. PV voltage [DC+ -> DC-] (UCPV ) | ≤ 1200 V |
Max. PV voltage [DC+/DC- -> PE] (UCPV ) | ≤ 1200 V |
Short-circuit current rating (ISCPV ) | 10 kA |
Nominal discharge current (8/20 µs) (In ) | 20 kA |
Max. discharge current (8/20 µs) (Imax ) | 40 kA |
Total discharge current (8/20 µs) [DC+/DC- -> PE] (Itotal ) | 40 kA |
Total discharge current (10/350 µs) [DC+/DC- -> PE] (Itotal ) | 12.5 kA |
Lightning impulse current (10/350 µs) [DC+ -> PE/DC- -> PE] (Iimp ) | 6.25 kA |
Voltage protection level [(DC+/DC-) -> PE] (UP ) | < 3.8 kV |
Voltage protection level [DC+ -> DC-] (UP ) | < 3.8 kV |
Response time (tA ) | ≤ 25 ns |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
For mounting on | 35 mm DIN rails acc. to EN 60715 |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 20 |
Dimensions | 4 module(s), DIN 43880 |
Approvals | KEMA, UL |
Type of remote signalling contact | Changeover contact |
Switching capacity (a.c.) | 250 V / 0.5 A |
Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
Extended technical data: | --------------------------------- |
– Use in DC battery storage systems up to ISCCR | ≤ 100 kA (t ≤ 5.83 ms) |
– Backup fuse for DC battery storage systems up to ISCCR | Bussman HLS 2000Vdc / 200 A 2+/A173 DST aR, manufacturer's Part No.: 170M2040 |
– Backup fuse for DC battery storage systems up to ISCCR | Mersen Protistor D122SD20C200QF 200A 2000V DC aR |
Product 900076 was added to Notepad.
Product 900076 was added to the cart.
SPD according to EN 61643-31 / IEC 61643-31 | type 1 + type 2 / class I + class II |
Max. PV voltage [DC+ -> DC-] (UCPV ) | ≤ 1500 V |
Max. PV voltage [DC+/DC- -> PE] (UCPV ) | ≤ 1500 V |
Short-circuit current rating (ISCPV ) | 10 kA |
Nominal discharge current (8/20 µs) (In ) | 20 kA |
Max. discharge current (8/20 µs) (Imax ) | 40 kA |
Total discharge current (8/20 µs) [DC+/DC- -> PE] (Itotal ) | 40 kA |
Total discharge current (10/350 µs) [DC+/DC- -> PE] (Itotal ) | 12.5 kA |
Lightning impulse current (10/350 µs) [DC+ -> PE/DC- -> PE] (Iimp ) | 6.25 kA |
Voltage protection level [(DC+/DC-) -> PE] (UP ) | < 4.5 kV |
Voltage protection level [DC+ -> DC-] (UP ) | < 4.5 kV |
Response time (tA ) | ≤ 25 ns |
Operating temperature range (TU ) | -40 °C ... +80 °C |
Operating state / fault indication | green / red |
Number of ports | 1 |
Cross-sectional area (min.) | 1.5 mm2 solid / flexible |
Cross-sectional area (max.) | 35 mm2 stranded / 25 mm2 flexible |
For mounting on | 35 mm DIN rails acc. to EN 60715 |
Enclosure material | thermoplastic, red, UL 94 V-0 |
Place of installation | indoor installation |
Degree of protection | IP 20 |
Dimensions | 4 module(s), DIN 43880 |
Approvals | KEMA, UL |
Type of remote signalling contact | changeover contact |
Switching capacity (a.c.) | 250 V / 0.5 A |
Switching capacity (d.c.) | 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A |
Cross-sectional area for remote signalling terminals | max. 1.5 mm2 solid / flexible |
Extended technical data: | --------------------------------- |
– Use in DC battery storage systems up to ISCCR | ≤ 100 kA (t ≤ 5.83 ms) |
– Backup fuse for DC battery storage systems up to ISCCR | Bussman HLS 2000Vdc / 200 A 2+/A173 DST aR, manufacturer's Part No.: 170M2040 |
– Backup fuse for DC battery storage systems up to ISCCR | Mersen Protistor D122SD20C200QF 200A 2000V DC aR |